44,500.00 / Unit

1 Unit (MOQ)

Business Type Supplier, Retailer, Wholesaler, Importer
Brand Name Contec
Model Number TLC5000
Number of Channels 12 Channels
Click to view more

Product Details

Sampling Rate
10000Hz
Sampling Accuracy
12 Bit
Recording Time
24 H
Power
2 Batteries in Size 5
Interface
USB2.0
Scale Voltage
1mV±5%
Standard Sensitivity
10 mm/mV±5%
Noise Level
≤30μV
CMRR
≥60dB
Feathers of Low Frequency
Time constant>3.2s
Scan Speed
25 mm/s±5>#/span###
Enduring Polarization Voltage
±300mV
Least Measure Signal
50 µV p-p
Product Safety Type
Type B (Internally Powered)
Size
111 mm(L)*60 mm(W)*25 mm(H)
Net Weight
102g (Without battery)

The Contec TLC5000 24hr Holter monitor is a 12 Channel ECG Quick and accurate analysis system With 12 leads synchro analysis, QRS search can be more exact. There are more than 10 templates as an atrial premature beat module in Contec TLC5000, 24hr Holter monitor. ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module, etc., and multiplicate User-defined templates could almost identify every kind of pathological waveforms. Contec TLC5000, 24hr Holter monitor has Optional main channel. Agile and exact “Atrial Fibrillation” analysis. The function of pacing analysis could analyze all pacemakers. in Contec TLC5000, 24hr Holter monitor Many pacing modules have been added. Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis. The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour long ECG. it Prints reports expediently. With the function of ST-segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally. “Sleep breath pause syndrome analysis”, the physician could print sleep asphyxia analysis report and diagnose. “HRT” analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately. “T Wave alternation” analysis is an important index on judging and preventing Arrhythmia. The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.

 

Key features Of Contec TLC5000 24hr Holter monitor:-

  • The recorder can work stably, is dependable and durable.
  • Be provided with the capability of anti-jamming and shock-pro.
  • Small volume with OLED screen. The resolution is 160*128. 
  • Be provided with functions of waveform preview, record review, and event marking. 
  • Accurate record of the start time of the data sampled owing to the real-time clock itself. 
  • Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data. 
  • The maximum capability can be 2 GB.
  • The average review time of a single case can be less than 40 seconds by using an interface of USB 2.0.
  • Record waveform details in extenso by the design of high precision and sampling frequency.
  • Record the state of the pacemaker exactly by the higher sampling frequency.
  • Record 24-hour DECG with the same standard of the ECG.